Siemens - 6ES7155-6AU00-0DN0
Siemens - 6ES7155-6AU00-0DN0
Regular price
€222,07 EUR
Regular price
Sale price
€222,07 EUR
Couldn't load pickup availability
Low stock: 5 left
SIMATIC ET 200SP IM 155-6 PN HS
General information | ||
Product type designation | IM 155-6 PN HS | |
HW functional status | From FS02 | |
Firmware version | V4.0 | |
FW update possible | Yes | |
Product function | ||
I&M data | Yes; I&M0 to I&M3 | |
Module swapping during operation (hot swapping) | Yes; Multi-hot swapping | |
Isochronous mode | Yes | |
IRT | Yes | |
Engineering with | ||
STEP 7 TIA Portal configurable/integrated from version | V14 | |
STEP 7 configurable/integrated from version | V5.5 SP4 | |
PROFINET from GSD version/GSD revision | GSDML V2.32 | |
Configuration control | ||
via dataset | Yes | |
Supply voltage | ||
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | |
Reverse polarity protection | Yes | |
Short-circuit protection | Yes | |
Mains buffering | ||
Mains/voltage failure stored energy time | 5 ms | |
Input current | ||
Current consumption, max. | 500 mA | |
Inrush current, max. | 4.5 A | |
I²t | 0.09 A²·s | |
Power loss | ||
Power loss, typ. | 1.7 W | |
Address area | ||
Address space per module | ||
Address space per module, max. | 32 byte; For input and output data respectively | |
Address space per station | ||
Address space per station, max. | 968 byte | |
Hardware configuration | ||
Rack | ||
Quantity of operable ET 200SP modules, max. | 30 | |
Quantity of operable ET 200AL modules, max. | 0 | |
Submodules | ||
Number of submodules per station, max. | 125 | |
Interfaces | ||
Number of PROFINET interfaces | 1; 2 ports (switch) | |
1. Interface | ||
Interface types | ||
RJ 45 (Ethernet) | Yes; with BusAdapter | |
Number of ports | 2; with BusAdapter | |
integrated switch | Yes | |
BusAdapter (PROFINET) | Yes; BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ/RJ45, BA SCRJ/FC, BA 2x LC, BA LC/RJ45, BA LC/FC | |
Protocols | ||
PROFINET IO Device | Yes | |
Open IE communication | Yes | |
Media redundancy | Yes; PROFINET MRP client / HRP client | |
PROFINET IO Device | ||
Services | ||
IRT | Yes; 125 µs to 4 ms in 125 µs frame | |
PROFIenergy | Yes | |
Prioritized startup | Yes | |
Shared device | Yes | |
Number of IO Controllers with shared device, max. | 4 | |
Interface types | ||
RJ 45 (Ethernet) | ||
Transmission procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | |
100 Mbps | Yes | |
Autonegotiation | Yes | |
Autocrossing | Yes | |
Protocols | ||
Supports protocol for PROFINET IO | Yes | |
PROFIsafe | Yes | |
PROFIBUS | No | |
EtherNet/IP | No | |
Modbus TCP | No | |
Redundancy mode | ||
PROFINET system redundancy (S2) | No | |
H-Sync forwarding | Yes | |
Media redundancy | ||
MRP | Yes | |
MRPD | Yes | |
Open IE communication | ||
TCP/IP | Yes | |
SNMP | Yes | |
LLDP | Yes | |
Isochronous mode | ||
Equidistance | Yes | |
shortest clock pulse | 125 µs | |
max. cycle | 4 ms | |
Bus cycle time (TDP), min. | 125 µs | |
Jitter, max. | 0.25 µs | |
Interrupts/diagnostics/status information | ||
Status indicator | Yes | |
Alarms | Yes | |
Diagnostics function | Yes | |
Diagnostics indication LED | ||
RUN LED | Yes; green LED | |
ERROR LED | Yes; red LED | |
MAINT LED | Yes; Yellow LED | |
Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED | |
Connection display LINK TX/RX | Yes; 2x green link LEDs on BusAdapter | |
Potential separation | ||
between backplane bus and electronics | No | |
between PROFINET and all other circuits | Yes; 1500 V AC (type test) | |
between supply and all other circuits | No | |
Permissible potential difference | ||
between different circuits | Safety extra low voltage SELV | |
Isolation | ||
Isolation tested with | 707 V DC (type test) | |
Standards, approvals, certificates | ||
Network loading class | 3 | |
Ecological footprint | ||
environmental product declaration | Yes | |
Global warming potential | ||
global warming potential, (total) [CO2 eq] | 105 kg | |
global warming potential, (during production) [CO2 eq] | 13.7 kg | |
global warming potential, (during operation) [CO2 eq] | 91.9 kg | |
global warming potential, (after end of life cycle) [CO2 eq] | -0.617 kg | |
Ambient conditions | ||
Ambient temperature during operation | ||
horizontal installation, min. | -25 °C; No condensation | |
horizontal installation, max. | 60 °C | |
vertical installation, min. | -25 °C; No condensation | |
vertical installation, max. | 50 °C | |
Altitude during operation relating to sea level | ||
Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual | |
connection method | ||
ET-Connection |