Siemens - 6ES7223-1QH32-0XB0

Siemens - 6ES7223-1QH32-0XB0

Regular price €164,10 EUR
Regular price Sale price €164,10 EUR
Sale Sold out

Low stock: 4 left

SIMATIC S7-1200 SM 1223 8 DI AC 120/230V 8 DO Relay 2A

General information
Product type designation SM 1223, DI 8x120/230 V AC, DQ 8x relay
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Input current
from backplane bus 5 V DC, max. 120 mA
output voltage / header
supply voltage of the transmitters / header
present Yes
Power loss
Power loss, typ. 7.5 W
Digital inputs
Number of digital inputs 8
in groups of 4
Input characteristic curve in accordance with IEC 61131, type 1 Yes
Number of simultaneously controllable inputs
all mounting positions
up to 40 °C, max. 8
horizontal installation
up to 40 °C, max. 8
up to 50 °C, max. 8
vertical installation
up to 40 °C, max. 8
Input voltage
Type of input voltage AC
Rated value (AC) 120/230 V AC
for signal "0" 20 V AC at 1 mA
for signal "1" 79 V AC at 2.5 mA
Input current
for signal "0", max. (permissible quiescent current) 1 mA
for signal "1", min. 2.5 mA
for signal "1", typ. 9 mA
Input delay (for rated value of input voltage)
for standard inputs
parameterizable Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four
for interrupt inputs
parameterizable Yes
Cable length
shielded, max. 500 m
unshielded, max. 300 m
Digital outputs
Number of digital outputs 8
in groups of 4
Short-circuit protection No; to be provided externally
Switching capacity of the outputs
with resistive load, max. 2 A
on lamp load, max. 30 W with DC, 200 W with AC
Output voltage
Rated value (DC) 5 V DC to 30 V DC
Rated value (AC) 5 V AC to 250 V AC
Output current
for signal "1" rated value 2 A
for signal "1" permissible range, max. 2 A
Output delay with resistive load
"0" to "1", max. 10 ms
"1" to "0", max. 10 ms
Total current of the outputs (per group)
horizontal installation
up to 50 °C, max. 8 A; Current per mass
Relay outputs
Number of relay outputs 8
Rated supply voltage of relay coil L+ (DC) 24 V
Number of operating cycles, max. mechanically 10 million, at rated load voltage 100 000
Switching capacity of contacts
with inductive load, max. 2 A
on lamp load, max. 30 W with DC, 200 W with AC
with resistive load, max. 2 A
Cable length
shielded, max. 500 m
unshielded, max. 150 m
Interrupts/diagnostics/status information
Alarms
Diagnostic alarm Yes
Diagnostics indication LED
for status of the inputs Yes
for status of the outputs Yes
Potential separation
Potential separation digital inputs
between the channels, in groups of 2
Potential separation digital outputs
between the channels Relays
between the channels, in groups of 2
between the channels and backplane bus 1 500 V AC for 1 minute
Permissible potential difference
between different circuits 750 V AC for 1 minute
Degree and class of protection
IP degree of protection IP20
Standards, approvals, certificates
CE mark Yes
CSA approval Yes
UL approval Yes
cULus Yes
FM approval Yes
RCM (formerly C-TICK) Yes
KC approval Yes
Marine approval Yes
Ecological footprint
environmental product declaration Yes
Global warming potential
global warming potential, (total) [CO2 eq] 123 kg
global warming potential, (during production) [CO2 eq] 12.1 kg
global warming potential, (during operation) [CO2 eq] 111 kg
global warming potential, (after end of life cycle) [CO2 eq] -0.434 kg
Ambient conditions
Free fall
Fall height, max. 0.3 m; five times, in product package
Ambient temperature during operation
min. -20 °C
max. 60 °C; Number of simultaneously activated outputs: 4 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 8 at 55 °C horizontal or 45 °C vertical
horizontal installation, min. -20 °C
horizontal installation, max. 60 °C
vertical installation, min. -20 °C
vertical installation, max. 50 °C
permissible temperature change 5°C to 55°C, 3°C / minute
Ambient temperature during storage/transportation
min. -40 °C
max. 70 °C
Air pressure acc. to IEC 60068-2-13
Storage/transport, min. 660 hPa
Storage/transport, max. 1 080 hPa
Relative humidity
Operation at 25 without condensation, max. 95 %
connection method
View full details